The organization block MC?PreServo [OB67] can be programmed and is called in the application cycle configured at the MC?Servo [OB91]. The MC?PreServo [OB67] is called directly before the MC?Servo [OB91].
Via the organization block, you can read out the configured application cycle (information in μs).
Optimized start information:
Name | Data type | Meaning | |
---|---|---|---|
Initial_Call | BOOL | TRUE | In the first call of this OB during transition from STOP to RUN |
PIP_Input | BOOL | TRUE | The associated process image input is up-to-date. |
PIP_Output | BOOL | TRUE | The associated process image output was transferred to the outputs in time after the last cycle. |
IO_System | USINT | Number of the distributed I/O system triggering the interrupt | |
Event_Count | INT | n | Number of lost cycles |
-1 | An unknown number of cycles has been lost, e.g. because the cycle has changed. | ||
Synchronous | BOOL | TRUE | The MC?Servo [OB91] is called synchronously with a bus system. |
CycleTime | UDINT | Display of the application cycle configured for the MC?Servo [OB91] in ns |
詞條
詞條說明
循環(huán)時間和較大循環(huán)時間(循環(huán)監(jiān)視時間)
循環(huán)時間和較大循環(huán)時間(循環(huán)監(jiān)視時間)功能循環(huán)時間是指操作系統(tǒng)執(zhí)行循環(huán)程序以及中斷此循環(huán)的所有程序段所需的時間。程序執(zhí)行會被以下事件中斷:時間錯誤和 2 次較大循環(huán)時間錯誤系統(tǒng)活動,如過程映像較新因此,每個循環(huán)的循環(huán)時間 (Tcyc) 均不相同。下圖顯示了 S7-1500 CPU 不同循環(huán)時間 (TZ1 ≠ TZ2) 的示例:在當(dāng)前循環(huán)中,將由一個時間錯誤(如,OB?80)中斷該循環(huán) O
創(chuàng)建類型的編輯版本如果要對面板或 HMI 用戶數(shù)據(jù)類型的類型進(jìn)行編輯,則需為該類型創(chuàng)建“開發(fā)中”(In work) 版本。并在庫視圖中對新版本進(jìn)行編輯。要檢查所做更改的兼容性,則需在發(fā)布前自動執(zhí)行一致性檢查。要求在“庫”(Libraries) 任務(wù)卡或庫視圖中打開項(xiàng)目庫。操作步驟要為某個類型創(chuàng)建新的開發(fā)版,請按以下步驟操作:右鍵單擊該類型或該類型的版本。在快捷菜單中選擇“編輯類型”(Edit ty
巡視窗口巡視窗口的功能有關(guān)所選對象或所執(zhí)行操作的附加信息均顯示在巡視窗口中。巡視窗口的布局下圖顯示了巡視窗口的組成部分:①“屬性”選項(xiàng)卡②“信息”選項(xiàng)卡③“診斷”選項(xiàng)卡④“屬性”選項(xiàng)卡內(nèi)的區(qū)域?qū)Ш舰荨皩傩浴边x項(xiàng)卡的內(nèi)容①“屬性”選項(xiàng)卡②“信息”選項(xiàng)卡③“診斷”選項(xiàng)卡④瀏覽選項(xiàng)卡內(nèi)的其它選項(xiàng)卡(僅在“信息”(Info) 和“診斷”(Diagnostics) 選項(xiàng)卡中可用)⑤工具欄(僅在“信息”(In
將更改保存到與 Teamcenter 相連的全局庫中要求需滿足以下要求:TIA Portal 已連接 Teamcenter。全局庫以“讀/寫”模式打開。所選擇的全局庫已連接到 Teamcenter 且進(jìn)行了更改。全局庫不支持多選。提示請注意以下事項(xiàng):TIA Portal 與 Teamcenter 之間無連接時,“Teamcenter > 保存”(Teamcenter > Save) 命
公司名: 上海騰希電氣技術(shù)有限公司
聯(lián)系人: 田禮科
電 話: 021-37660026
手 機(jī): 13681875601
微 信: 13681875601
地 址: 上海松江上海市松江區(qū)廣富林路4855弄星月大業(yè)**88號4樓
郵 編:
網(wǎng) 址: shtxjd.cn.b2b168.com
公司名: 上海騰希電氣技術(shù)有限公司
聯(lián)系人: 田禮科
手 機(jī): 13681875601
電 話: 021-37660026
地 址: 上海松江上海市松江區(qū)廣富林路4855弄星月大業(yè)**88號4樓
郵 編:
網(wǎng) 址: shtxjd.cn.b2b168.com
¥6300.00
網(wǎng)課專享 教學(xué)一體機(jī) 21.5寸
¥1980.00