SIMATIC WinCC V16
SIMATIC WinCC Unified V16 is our new visualization platform in TIA Portal and supplements our existing WinCC product portfolio.
SIMATIC WinCC Unified is a completely new visualization system which allows you to successfully master the challenges posed by digitalization in mechanical and plant engineering. State-of-the-art hardware and software technologies make this possible now and in the future. Proven engineering in TIA Portal, the latest web technology and high performance reserves for the coming years, along with the freedom that you can implement your ideas as you wish.
More details are provided in the following SIOS entry: WinCC Unified V16 (109771777)
The innovations for other TIA Portal products are described in the following entries:
SIMATIC STEP 7 V16 (109771628)
TIA Portal V16 (109771626)
? WinCC Engineering:
Starting with Version V16, the existing Comfort/Advanced/Professional Engineering license can also be used for configuring WinCC Unified.
Note:
WinCC United is included on the installation DVD for WinCC Basic/Comfort/Advanced/Unified and can be additionally installed.
With WinCC Professional Engineering, we include the WinCC Basic/Comfort/Advanced/Unified Engineering DVD in the delivery. Parallel installation of WinCC Professional Engineering and WinCC Unified Engineering is not possible.
? WinCC Advanced: ProDiag system function "ShowBlockInTIAPortal"
System function "ShowBlockInTIAPortal", the "TIA Portal project path" parameter can be supplied with a dynamic value from a tag
? Comfort/Mobile/Advanced – Hiding of navigation bar and frame of the HTML Browser Control
The HTML Browser Control can be configured with V16 such that the content displayed in the HTML Browser Control is displayed as a full screen without navigation bar.
? Comfort/Mobile/Advanced – Deactivation of the focus color for the message selected in the message display
The message display can be configured with V16 such that the configured message colors of the currently selected message are no longer overlaid by the focus color.
? Comfort Panel / Mobile Panel: OnScreenKeyboard:
Selection of international keyboard layouts for panel input
Hidden entry on connection via Sm@rtServer for devices with full screen keyboard
Choice between full screen or small keyboard with 7" and 9"
? Comfort Panel / Mobile Panel: Printing barcodes
The legibility of barcodes on a printout can be improved by using the ProSave Add-On
? Comfort Panel / Mobile Panel: Update of PDF control and PDF printer
Use of current PDF versions
? HMI Option + V3: New functions available:
Support of KTP Mobile Panels
HMI Option Plus V3: New functions available:
Extension of available RFID card readers
Date display for the last project download
Changing of the standard gateway from the Runtime software
PC configuration including automated download and update of data from the panel
? WinCC Professional: Archiving of string tags
Archiving of string tags
? WinCC Professional: Tags / communication
Improvements during auto-start in the server <> client communication
Remote communication can be deactivated via Simatic Shell
New tag simulator
? WinCC Professional: ProDiag extensions
Hierarchical comments are displayed in the PLC Code Viewer
The operand values upon slice access are displayed
The connection status server<>client is displayed in the controls
? WinCC Professional: Miscellaneous
WebBrowser IE 11 compatible
The connection status of the PLC can be displayed via a system tag.
Migration: Migration possible from WinCC V7.5 to WinCC Professional V16
SQL Server: Version change from SQL Server 2014 SP2 to SQL Server 2016 SP2
SIMATIC IPC127E
SIMATIC IPC627E
SIMATIC IPC677E
SIMATIC IPC647E
SIMATIC IPC847E
You can find information on the SIMATIC IPCs here: SIMATIC IPCs
Information
Device support - Changed device support
The following HMI devices are no longer supported starting with TIA Portal V16:
Mobile Panel 177, Mobile Panel 277, Mobile Panel 277 IWLAN
Furthermore, HMI devices (Basic Panels, Comfort Panels, Mobile Panels and WinCC Runtime Advanced) that are configured with device version V12.x are no longer supported as of TIA Portal V16.'
To recover projekts of operater panels which include V12.x images in TIA Portal V16, please convert the project of the involved panel – before opening – to an image version V13.x or higher.
Provision of panel images
In order to optimize the size of the standard installation, starting with TIA Portal V16 all versions of the HMI device images have been moved to an additional DVD.
If you want to transfer HMI devices with these versions, install the respective image files.
The image files can be obtained and installed via:
Installation of DVD "SIMATIC WinCC Panel Images V16
Download of DVD "SIMATIC WinCC Panel Images V16": 109772803
WinCC Runtime Advanced
SIMATIC WinCC Runtime Advanced is the high-performance visualization software for simple, machine-level visualization tasks. It can be used as a single-user solution for all automation applications in factory automation, process automation and building automation.
WinCC Runtime Professional
SIMATIC WinCC Runtime Professional is a PC-based operator control and monitoring system for visualization and operation of processes, production sequences, machines and plants in all industries – ranging from simple single-user systems to distributed multi-user systems and cross-location solutions with web clients.
SIMATIC WinCC Runtime Professional is based on a further development of WinCC Runtime V7.4 and obtains access to WinCC archives via OPC HDA, OPC A&E / OPC XML Server and WinCC OLE DB/OLE DB. The basic package also includes runtime APIs for use of the open programming interfaces.
Runtime options for WinCC
Options for scalable plant configurations
WinCC Server for WinCC Runtime Professional:
For setup of high-performance client-server systems
WinCC Redundancy for Runtime Professional:
For setup of high-performance, redundant client-server systems
WinCC Client for WinCC Runtime Professional:
For setup of high-performance client-server systems
WinCC WebNavigator for WinCC Runtime Professional:
For operator control and monitoring of plants over the Internet, company intranet or LAN
WinCC Recipes for WinCC Runtime Advanced /WinCC Runtime Professional:
For management of data records
WinCC Logging for WinCC Runtime Advanced / WinCC Runtime Professional:
For management of data records
WinCC Audit for WinCC Runtime Advanced as well as SIMATIC Panels:
For recording of operator actions in an audit trail and electronic signature
WinCC Sm@rtServer for SIMATIC Basic Panels:
For remote access to panel / single-user station, options for Runtime extensions
SIMATIC Logon:
Central management of WinCC users throughout the plant, options for IT and business integration – Plant Intelligence
WinCC DataMonitor for WinCC Runtime Professional:
For display and evaluation of current process statuses and historical data on office PCs using standard tools, options for customized system extensions
SIMATIC Information Server:
Web-based, integrated reporting from production to management, based on archived data
WinCC Process Historian:
Central, scalable long-term archive for the whole plant
WinCC WebUX:
For operator control and monitoring of plants, independent of platforms and browsers, via the Internet, company intranet or LAN
Options | WinCC RT Advanced | WinCC RT Professional | SIMATIC Panels |
---|---|---|---|
SIMATIC ProDiag | X | X | X |
SIMATIC Logon | X | X | X |
WinCC Logging | X | X | X1) |
WinCC Recipes | X | X | X1) |
WinCC Audit | X | - | X |
WinCC Sm@rtServer | X1) | - | X1) |
WinCC DataMonitor | - | X | - |
WinCC IndustrialDataBridge | - | X | - |
SIMATIC Information Server | - | X | - |
SIMATIC Process Historian | - | X | - |
WinCC Redundancy | - | X | - |
WinCC Server/WinCC Client | - | X | - |
WinCC WebNavigator | - | X | - |
WinCC WebUX | - | X | - |
X - possible
1) integrated in basic system
WinCC Basic/Comfort/Advanced/Professional V16 are released for use with the following operating systems (64-bit only):
Operating system | WinCC Basic | WinCC Com. / Adv. | WinCC Prof. | |||
---|---|---|---|---|---|---|
| 32-bit | 64-bit | 32-bit | 64-bit | 32-bit | 64-bit |
Windows 7 Home Premium SP1 | - | YES | - | - | - | - |
Windows 7 Professional SP1 | - | YES | - | YES | - | - |
Windows 7 Enterprise SP1 | - | YES | - | YES | - | - |
Windows 7 Ultimate SP1 | - | YES | - | YES | - | - |
Windows Embedded Std 7 SP1 | - | - | - | - | - | - |
|
|
|
|
|
| |
Windows 8.1 Professional | - | - | - | - | - | - |
Windows 8.1 Enterprise | - | - | - | - | - | - |
|
|
|
|
|
| |
Windows 10 Home Version 1809 / 1903 (OS Build 17763/ 18362) | - | YES | - | - | - | - |
Windows 10 Pro Version 1809 / 1903 (OS Build 17763/ 18362) | - | YES | - | YES | - | YES |
Windows 10 Enterprise Version 1809 / 1903 (OS Build 17763/ 18362) | - | YES | - | YES | - | YES |
Windows 10 Enterprise LTSB 2015 (OS Build 10240) | - | YES | - | YES | - | YES |
Windows 10 Enterprise LTSB 2016 (OS Build 14393) | - | YES | - | YES | - | YES |
Windows 10 Enterprise LTSC 2019 (OS Build 17763) | - | YES | - | YES | - | YES |
|
|
|
|
|
| |
Windows Server 2008 R2 StdE SP1 (full installation) | - | - | - | - | - | - |
Windows Server 2012 R2 x64 StdE (full installation) | - | YES | - | YES | - | YES |
Windows Server 2016 Standard (full installation) | - | YES | - | YES | - | YES |
Windows Server 2019 Standard (full installation) | - | YES | - | YES | - | YES |
| Processor | RAM | Graphics | Operating system |
---|---|---|---|---|
Recommended PC/PG hardware | At least Intel? Core? i5-6440M 3.4 GHz or comparable | 16 GB (at least 4 GB) | 1920 x 1080 | 64-bit |
WinCC Runtime Advanced V16 and WinCC Runtime Professional V16 are released for use with the following operating systems:
Operating system | RT Adv | RT Prof | ||
---|---|---|---|---|
| 32-bit | 64-bit | 32-bit | 64-bit |
Windows 7 Professional SP1 | YES | YES | * | - |
Windows 7 Enterprise SP1 | YES | YES | * | - |
Windows 7 Ultimate SP1 | YES | YES | * | - |
Windows Embedded Std 7 SP1 | YES | YES | * | - |
|
|
|
|
|
Windows 8.1 Professional | - | YES | - | - |
Windows 8.1 Enterprise | - | YES | - | - |
|
|
|
|
|
Windows 10 Pro Version 1809 / 1903 (OS Build 17763 / 18362) | - | YES | - | YES |
Windows 10 Enterprise Version 1809 / 1903 (OS Build 16299 / 17134) | - | YES | - | YES |
Windows 10 Enterprise LTSB 2015 (OS Build 10240) | - | YES | - | YES |
Windows 10 Enterprise LTSB 2016 (OS Build 14393) | - | YES | - | YES |
Windows 10 Enterprise LTSC 2019 (OS Build 17763) | - | YES | - | YES |
|
|
|
|
|
Windows Server 2008 R2 StdE SP1 (full installation) | - | YES | - | - |
Windows Server 2012 R2 x64 StdE (full installation) | - | YES | - | YES |
Windows Server 2016 Standard (full installation) | - | YES | - | YES |
Windows Server 2019 Standard (full installation) | - | YES | - | YES |
*) only for WinCC Client / WebNavigator Client / Data Monitor Client / WebUX Client
| Processor | RAM | Graphics | Operating system |
---|---|---|---|---|
Recommended PC hardware for WinCC Advanced (32-bit) | At least Intel? Atom? 1.3 GHz or comparable | At least 4 GB | 1280 x 800 | 32-bit |
Recommended PC hardware for WinCC Advanced (64-bit) | At least Intel? Celeron? 1.4 GHz or comparable | At least 4 GB | 1280 x 800 | 64-bit |
Recommended PC hardware for WinCC Professional (32-bit) | At least Intel? DualCore? i3 1.6 GHz or comparable | At least 4 GB | 1366 x 768 | 32-bit |
Recommended PC hardware for WinCC Professional (64-bit) | At least Intel? DualCore? i3 1.6 GHz or comparable | At least 8 GB | 1366 x 768 | 64-bit |
You can find the compatibility statements on automation and drive technology in the compatibility tool of Industry Online Support. Entry ID 64847781
Quick link to the compatibility tool
Link for Unified-Trainings:
SITRAIN course: SIMATIC WinCC (TIA Portal) machine-level for Comfort Panels and WinCC Runtime Advanced (Entry ID: 109758624)
SITRAIN advanced course: SIMATIC WinCC (TIA Portal) machine-level for Comfort Panels and WinCC Runtime Advanced (Entry ID: 109758626)
SITRAIN course: SIMATIC WinCC Professional, SCADA in the TIA Portal (Entry ID: 109758626)
TIA Portal - An overview of the most important documents and links – Visualization (Entry ID: 90939751)
Machine-level operator control and monitoring in Online Support (Entry ID: 93905586)
Compatibility Tool (Entry ID: 64847781)
The products with article numbers and prices are listed in the attached file.
Product | Article number |
---|---|
SIMATIC WinCC Basic/Comfort/Advanced/Unified V16 Trial License | 6AV2102-0AA06-0AA7 |
SIMATIC WinCC Professional V16 Trial License | 6AV2103-0AA06-0AA7 |
Here you can download a trial version of SIMATIC STEP 7 / WinCC V16 Engineering and test it for 21 days: 109772803
We want to make it as easy as possible for our TIA Portal V15/15.1 customers to switch to TIA Portal V16 and keep their engineering software up-to-date. That is why we are offering an attractive SUS transition offer for these TIA Portal products as download for a limited time:
SUS Download Produkt | Artikelnummer |
---|---|
WinCC Comfort Download | 6AV6612-0AA00-0AY0 |
WinCC Advanced Download | 6AV6613-0AA00-0AY0 |
WinCC Professional 512 PowerTags Download | 6AV2103-0DA00-0AY0 |
WinCC Professional 4096 PowerTags Download | 6AV2103-0HA00-0AY0 |
WinCC Professional max. PowerTags Download | 6AV2103-0XA00-0AY0 |
WinCC Runtime Professional Client | 6AV2107-0DB00-0AY0 |
WInCC Runtime Professional | 6AV2105-0XA00-0AY0 |
詞條
詞條說明
用于具有高可用性或高功能安全要求應(yīng)用的 CPU可用于實(shí)現(xiàn)安全等級(jí)達(dá)到 SIL 3 (IEC 61508) 以及 PLe (ISO 13849) 的故障安全功能。配有海量程序數(shù)據(jù)存儲(chǔ)器,可以實(shí)現(xiàn)廣泛的應(yīng)用。具有較高處理速度,適用于二進(jìn)制和浮點(diǎn)運(yùn)算用作分布式 I/O 的* PLC支持分布式組態(tài)中的 PROFIsafePROFINET IO RT 接口,帶 2 端換機(jī)兩個(gè)帶獨(dú)立 IP 地址的、額外的
移動(dòng) CP 的喚醒通過“授權(quán)電話號(hào)碼”喚醒的權(quán)限僅當(dāng)根據(jù)電話號(hào)碼對(duì)發(fā)送通信伙伴進(jìn)行授權(quán)的情況下,CP 才會(huì)接受喚醒 SMS 或喚醒呼叫。在 STEP 7 中的“授權(quán)電話號(hào)碼”列表中為 CP 組態(tài)這些電話號(hào)碼。提示STEP 7 項(xiàng)目中的“授權(quán)電話號(hào)碼”此處輸入的電話號(hào)碼可使傳輸此電話號(hào)碼的發(fā)送方有權(quán)觸發(fā)連接建立請(qǐng)求。如果在列表中輸入星號(hào) (*),CP 將接受所有發(fā)送方發(fā)來的 SMS 消息。如果列表為
點(diǎn)對(duì)點(diǎn)使用自由口接收數(shù)據(jù)
使用自由口接收數(shù)據(jù)*消息的開始對(duì)于使用自由口的數(shù)據(jù)傳輸,可在多種不同的開始標(biāo)準(zhǔn)中進(jìn)行選擇。 開始標(biāo)準(zhǔn)可定義幀的開始時(shí)間。 一旦符合指示消息開始的標(biāo)準(zhǔn),就將掃描數(shù)據(jù)流的消息結(jié)束標(biāo)準(zhǔn)。 在此選擇與發(fā)送通信伙伴屬性對(duì)應(yīng)的設(shè)置。有兩種不同的方法可用于檢測(cè)消息的開始:以任意字符開始任意字符均可用于定義消息的開始(默認(rèn)設(shè)置)。這意味著在通信開始時(shí)發(fā)送的**個(gè)字符,或檢測(cè)到幀結(jié)束后的**個(gè)字符將被識(shí)別為消息的
有關(guān)使用 TIA Portal Teamcenter Gateway 的注意事項(xiàng)
有關(guān)使用 TIA Portal Teamcenter Gateway 的注意事項(xiàng)內(nèi)容在線幫助中未包含的信息和有關(guān)產(chǎn)品特性的重要信息。安裝 TIAPortalTeamcenterGateway有關(guān) TIA Portal Teamcenter Gateway 的安裝指南,請(qǐng)參見 TIA Portal Teamcenter Gateway 在線幫助中的“安裝與卸載 TIA Portal Teamcent
公司名: 上海騰希電氣技術(shù)有限公司
聯(lián)系人: 田禮科
電 話: 021-37660026
手 機(jī): 13681875601
微 信: 13681875601
地 址: 上海松江上海市松江區(qū)廣富林路4855弄星月大業(yè)**88號(hào)4樓
郵 編:
網(wǎng) 址: shtxjd.cn.b2b168.com
公司名: 上海騰希電氣技術(shù)有限公司
聯(lián)系人: 田禮科
手 機(jī): 13681875601
電 話: 021-37660026
地 址: 上海松江上海市松江區(qū)廣富林路4855弄星月大業(yè)**88號(hào)4樓
郵 編:
網(wǎng) 址: shtxjd.cn.b2b168.com
¥6300.00
網(wǎng)課專享 教學(xué)一體機(jī) 21.5寸
¥1980.00