F2D0-FB-Ex4.*F2-SP-IC*倍加福RD0-TI-EX8.FF.ST-Y1

    HCD2-FBPS-1.23.500
    Fieldbus Power Hub, Compact Power Supply Module
    
    Output: 21 ... 23 V/500 mA, Voltage limitation for Entity ic and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    HCD2-FBPS-1.500
    Fieldbus Power Hub, Compact Power Supply Module
    
    Output: 28 ... 30 V/500 mA, High-power trunk for high device count and long cable lengths, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    HD2-DM-A
    Fieldbus Power Hub, Advanced Diagnostic Module
    
    Comprehensive diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    HD2-GTR-4PA
    PROFIBUS Power Hub, Gateway Module
    
    PROFIBUS DP V1 / For 4 segments PA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Optional redundant configuration, Installation in Zone 2/Class I, Div. 2, Up to 12 Mbit/s, auto adapting
    
    KT-MB-GT2AD.FF
    Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface
    
    System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Common alarm handling, For FOUNDATION Fieldbus and PROFIBUS PA
    
    R-SP-E12
    Segment Protector for Cabinet Installation
    
    Segment Protector for Cabinet Installation, 12 increased safety outputs (Ex e), Short circuit current limitation per output, Segment Protector in Zone 1/Div. 2, Instruments in Zone 1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    ELS-1
    Enclosure Leakage Sensor
    Housing leakage sensor, for operation with FOUNDATION Fieldbus and PROFIBUS PA, Indication via LED and Advanced Diagnostics, Intrinsically safe, FISCO or Entity, For instrument or device coupler, Fits inside terminal compartment, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    HD2-DM-B
    Fieldbus Power Hub, Basic Diagnostic Module
    Basic monitoring for power supply output and health, Plug-in Module for the FieldConnex Power Hub, Plug and play - no engineering required, For online monitoring, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    KFD2-BR-1.PA.1500
    Basic Segment Coupler
    Output: 24 ... 26 V/400 mA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, Up to 1.5 MBit auto-adapting
    
    KLD0-SAA
    Voltage adjustment module
    Series voltage reducing module, Removable terminals, Polarity reversal protected, Installation in cabinet on DIN mounting rail, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    KLD2-FBPS-1.25.360
    Fieldbus Power Supply
    Output: 25 ... 27 V/360 mA, For most fieldbus applications, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1
    
    BP-FBPS-1.30.1
    Portable Fieldbus Battery
    Portable Fieldbus Battery, Adjustable output 15 ... 30 V/max.1 A , 8 hours operation at 500 mA without recharging, IP 54 - Rain and splash proof, Rugged housing for outdoor use, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    EI-0D2-10Y-10B
    Intrinsically safe Ethernet Isolator
    Galvanic Isolation I.S. to non-I.S. Port, 10/100 MBit/s according to IEEE 802.3/.3u, Installation in Zone 2, Ethernet in Zone 1 or Zone 0, Standard Ethernet patch or crossover cable, DIN-Rail mounted and OEM Version
    
    FBTA-228-BPFB-R-8R
    Compact Fieldbus Power Hub Motherboard for Invensys FBM 228
    8 segments, redundant, individual modules per segment, Customized for Invensys, FBM228, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
    
    FDH-1
    Fieldbus Diagnostic Handheld
    Fieldbus Diagnostic Handheld, Comprehensive diagnostics for the fieldbus physical layer, Handheld with display and integrated expert system, Fieldbus interface Ex ia, FISCO, Entity, and DART, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    HD2-DM-A.RO
    Fieldbus Power Hub, Advanced Diagnostic Module with Relay Output
    Diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Plug and play - no engineering required, For online monitoring, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    HD2-GTR-4PA.PN
    PROFINET Power Hub, Gateway Module
    Gateway PROFINET RT to 4 x PROFIBUS PA segments, Up to 32 devices per PROFIBUS PA segment, Installation in Zone 2/Class I, Div. 2, Ring and system redundancy, Integrated webserver for diagnostics
    
    KFD2-BR-Ex1.3PA.93
    Segment Coupler 1
    Output: 12.6 ... 13.4 V/100 mA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Intrinsically safe, Ex ia (FISCO or Entity), Installation in Zone 2/Class I, Div. 2, Fixed, high-availability terminator
    
    KLD2-FBPS-1.12.220
    Fieldbus Power Supply
    Output: 12 ... 13 V/220 mA, For battery or solar-powered applications, For demanding environmental conditions , Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1
    
    KLD2-PR-1.IEC
    Fieldbus Power Repeater
    Output: 24 ... 26 V/400 mA, For extension of fieldbus segments, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    KT-MB-DMA
    Advanced Diagnostic Module, Kit for Stand-Alone Operation
    Comprehensive diagnostics for the fieldbus physical layer, Module and motherboard for retrofit of any installation, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    KT-MB-GT2AD.FF.IO
    Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O
    System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Alarm handling and integrated I/O for cabinet monitoring/control, For FOUNDATION Fieldbus and PROFIBUS PA
    
    KT-SRT-FF
    Starter Kit for FOUNDATION Fieldbus H1 Infrastructure
    Starter Kit for FOUNDATION Fieldbus H1 Infrastructure, Complete hardware for connection of FOUNDATION Fieldbus H1 field devices to the host system of your choice, Output: 25 ... 28 V/360 mA, Connection of 6 field devices with individual short-circuit protection, High-power trunk for high device count and long cable lengths
    
    KT-SRT-PA
    Starter Kit for PROFIBUS PA Infrastructure
    Starter Kit for PROFIBUS PA Infrastructure, Complete hardware for connection of PROFIBUS PA field devices to a DP-Master, Output: 24 ... 26 V/400 mA, Connection of 6 field devices with individual short-circuit protection, High-power trunk for high device count and long cable lengths
    
    MBHC-FB-4R.YO.R
    Compact Fieldbus Power Hub Motherboard for Yokogawa ALF111
    Compact redundant Fieldbus Power Hub motherboard with redundant terminals for Yokogawa ALF111 on the right-hand side
    
    USB-FBPS-1.11.45.NI
    USB Fieldbus Power Supply
    USB Fieldbus Power Supply, Output: min. 11 V/45 mA, For 1...2 devices/test setups, In conjunction with NI PCMCIA-FBUS card, Permitted for Zone 2 operation, For FOUNDATION Fieldbus H1
    
    HD2-FBPS-1.500
    Fieldbus Power Hub, Power Supply Module
    Output: 28 ... 30 V/500 mA, High-power trunk for high device count and long cable lengths, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    HD2-FBPS-1.17.500
    Fieldbus Power Hub, Power Supply Module
    Output: 15 ... 17 V/500 mA, Voltage limitation for FISCO ic, Entity ic, also FNICO and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    HD2-FBPS-1.23.500
    Fieldbus Power Hub, Power Supply Module
    Output: 21 ... 23 V/500 mA, Voltage limitation for Entity ic and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    HD2-FBPS-1.25.360
    Fieldbus Power Hub, Power Supply Module
    Output: 25 ... 28 V/360 mA, Universal power supply for most applications, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    FBTA-228-BPFB-8
    Universal Fieldbus Power Hub, Motherboard for Invensys FBM 228
    8 segments, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Features for best ** quality, low heat dissipation, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    FBTA-228-BPFB-R-4R
    Universal Fieldbus Power Hub, Motherboard for Invensys FBM 228
    4 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Features for best ** quality, low heat dissipation, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    KLD2-PR-Ex1.IEC1
    Fieldbus Power Repeater
    Power supply of fieldbus segments according to IEC 61158-2, Signal repeater for fieldbus topologies in accordance to FISCO, 100 mA supply of the field side, Improves the fieldbus **, Extension of the transmission distance by means of opening a new fieldbus segment
    
    EI-0D2-10Y-10B-Y1
    Intrinsically safe Ethernet Isolator
    Galvanic Isolation I.S. to non-I.S. Port, 10/100 MBit/s according to IEEE 802.3/.3u, Installation in Zone 2, Ethernet in Zone 1 or Zone 0, Standard Ethernet patch or crossover cable, DIN-Rail mounted and OEM Version
    
    KLD2-PR-Ex1.IEC
    Fieldbus Power Repeater
    Power supply of fieldbus segments according to IEC 61158-2, Signal repeater for fieldbus topologies in accordance to Entity, 70 mA supply of the field side, Improves the fieldbus **, Extension of the transmission distance by means of opening a new fieldbus segment
    
    RD0-TI-EX8.FF.ST-Y1
    Temperature Multi-Input Device for Cabinet Installation
    Temperature Multi-Input Device for Cabinet Installation
    
    MB-FB-4R.HO.SC
    High-Density Fieldbus Power Hub, Motherboard for Honeywell C-Series
    4 segments, redundant, individual modules per segment, Customized for Honeywell, C-Series, High-power trunk: Live work on devices in any hazardous area, Optimized for size and quality, low heat dissipation, For FOUNDATION Fieldbus H1
    
    DP-LBF-I1.36.*
    Fieldbus Surge Protector for Cabinet Installation, Ex ia
    Modular: protection module easy to replace, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Protection module replaceable, interrupting or non-interrupting, Grounding of shield direct or via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F*-FT-Ex1
    Fieldbus Terminator, Field Installation, Ex ia
    Terminator in stainless steel housing, Intrinsically safe, FISCO and flameproof enclosure (Ex d), Installation on open cable gland, Choice of threads 20 mm, Pg 13.5 mm or 1/2" NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F*-LBF-D1.32
    Fieldbus Surge Protector, Field Installation, Ex d
    Surge Protector in stainless steel housing, Flameproof enclosure (Ex d) protection, Surge protection for '+' and '-' fieldbus lead, Choice of threads 20 mm or 1/2" NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F*-LBF-I1.32
    Fieldbus Surge Protector, Field Installation, Ex ia
    Surge Protector in stainless steel housing, Intrinsically safe, FISCO or Entity, Surge protection for '+' and '-' fieldbus lead, Choice of threads 20 mm or 1/2" NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F.FB0.P**.A**.1.0.***.***.****
    FieldBarrier Junction Box, Polyester (GRP)
    4, 8 or 12 outputs Ex ia, Impact resistance enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F.FB0.S**.A**.1.0.***.***.****
    FieldBarrier Junction Box, Stainless Steel
    4, 8 or 12 outputs Ex ia, Electropolished enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F.FB1.P14.A**.1.*.***.***.****
    FieldBarrier Junction Box, Polyester (GRP)
    8, 10, 12 outputs Ex ia, Impact resistance enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F.FB1.S14.A**.1.*.***.***.****
    FieldBarrier Junction Box, Stainless Steel
    8, 10, 12 outputs Ex ia, Electropolished enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F.MIO.P12.*12.F.*.***.***.**00
    Multi-Input/Output Junction Box, Polyester (GRP)
    For discrete inputs and outputs, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For FOUNDATION Fieldbus H1
    
    F.MIO.P12.*12.P.*.***.***.**00
    Multi-Input/Output Junction Box, Polyester (GRP)
    For discrete inputs and outputs, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For PROFIBUS PA
    
    F.MIO.S12.*12.F.*.***.***.**00
    Multi-Input/Output Junction Box, Stainless Steel
    For discrete inputs and outputs, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For FOUNDATION Fieldbus H1
    
    F.MIO.S12.*12.P.*.***.***.**00
    Multi-Input/Output Junction Box, Stainless Steel
    For discrete inputs and outputs, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For PROFIBUS PA
    
    F.SP5.P**.B**.1.0.***.***.***0
    Segment Protector Junction Box, Polyester (GRP)
    4 ... 12 outputs Ex ic (FISCO or Entity), Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F.SP5.S**.B**.1.0.***.***.***0
    Segment Protector Junction Box, Stainless Steel
    4 ... 12 outputs Ex ic (FISCO or Entity), Stainless steel, electropolished, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F.SPE.P**.A**.1.0.***.***.****
    Segment Protector Junction Box, Polyester (GRP)
    Connection of Ex d certified devices, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F.SPE.S**.A**.1.0.***.***.****
    Segment Protector Junction Box, Stainless Steel
    Connection of Ex d certified devices, Stainless steel, electropolished, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F.TI0.P12.*08.F.0.***.***.**00
    Temperature Multi-Input Junction Box, Polyester (GRP)
    8 channel universal temperature interface, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For FOUNDATION Fieldbus H1
    
    F.TI0.P12.*08.P.0.***.***.**00
    Temperature Multi-Input Junction Box, Polyester (GRP)
    8 channel universal temperature interface, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For PROFIBUS PA
    
    F.TI0.S12.*08.F.0.***.***.**00
    Temperature Multi-Input Junction Box, Stainless Steel
    8 channel universal temperature interface, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For FOUNDATION Fieldbus H1
    
    F.TI0.S12.*08.P.0.***.***.**00
    Temperature Multi-Input Junction Box, Stainless Steel
    8 channel universal temperature interface, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For PROFIBUS PA
    
    F.VC0.P21.A04.*.*.***.***.*000
    Valve Coupler Junction Box, Polyester (GRP)
    4 valve control and 8 position feedback **s, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F.VC0.S20.A04.*.*.***.***.*000
    Valve Coupler Junction Box, Stainless Steel
    4 valve control and 8 position feedback **s, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F2-JB-#.*
    Fieldbus junction box
    4 ... 8 outputs selectable, Installation in non-explosion hazardous area, Instruments in non-explosion hazardous area, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Supports FISCO and Entity
    
    F2-JB-I#.*
    Fieldbus junction box
    4 ... 8 outputs Ex ia, ib, Installation in Zone 1/Div. 1, Instruments in Zone 0...1/Div. 1, Trunk and spurs intrinsically safe, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F2-SP-IC*
    Fieldbus Segment Protector
    Fieldbus Segment Protector, 4 ... 10 outputs Ex ic (FISCO or Entity), Advanced fault isolation at the spur, Segment Protector in Zone 2, Instruments in Zone 2 or Zone 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F2D0-FB-Ex4.*
    FieldBarrier?
    4 outputs Ex ia IIC, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, Short circuit current limitation per output, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    F2D0-MIO-Ex12.FF.*
    Multi-Input/Output Device with Aluminum Housing
    For discrete inputs and outputs, Aluminum cast iron, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For FOUNDATION Fieldbus H1
    
    F2D0-MIO-Ex12.PA.*
    Multi-Input/Output Device with Aluminum Housing
    For discrete inputs and outputs, Aluminum cast iron, IP66, Configurable cable entries for bus lines and field ** lines, International approvals, For PROFIBUS PA
    
    F2D0-TI-Ex8.FF.*
    Temperature Multi-Input Device with Aluminum Housing
    For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1
    
    F2D0-TI-Ex8.PA.*
    Temperature Multi-Input Device with Aluminum Housing
    For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA
    
    MB-FB-GTR1*
    Fieldbus Power Hub, Gateway Motherboard
    For 2 gateway modules, For PROFIBUS PA, Redundant configuration, Installation in Zone 2/Class I, Div. 2, Spring terminals or screw terminals selectable
    
    MBHC-FB-4*
    Compact Fieldbus Power Hub, Motherboard, Common Interface
    4 segments, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
    
    MBHC-FB-4.GT*
    Fieldbus Power Hub, Motherboard for Gateway and Power Supply Modules
    4 segments, simplex, individual modules per segment, For PROFIBUS PA, For gateway and power supply modules, High-power trunk: Live work on devices in any hazardous area, Optional advanced diagnostics
    
    MBHC-FB-4.HSC*
    Compact Fieldbus Power Hub, Motherboard, Host System Connector
    4 segments, individual modules per segment, Customizable cable connections to any PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus and PROFIBUS PA
    
    MBHC-FB-4.YO*
    Compact Fieldbus Power Hub, Motherboard for Yokogawa ALF111
    4 segments, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
    
    MBHC-FB-4R*
    Compact Fieldbus Power Hub Motherboard with Common Interface
    4 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
    
    MBHC-FB-4R.HSC*
    Compact Fieldbus Power Hub, Motherboard, Host System Connector
    4 segments, redundant, individual modules per segment, Customizable cable connections to any PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus and PROFIBUS PA
    
    MBHC-FB-4R.YO*
    Compact Fieldbus Power Hub Motherboard for Yokogawa ALF111
    4 segments, redundant, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
    
    MBHC-FB-8R*
    Compact Fieldbus Power Hub, Motherboard, Common Interface
    8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
    
    MBHC-FB-8R.HSC*
    Compact Fieldbus Power Hub, Motherboard, Host System Connector
    8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
    
    MBHC-FB-8R.RH*
    Compact Fieldbus Power Hub, Motherboard, Redundant Host Terminals
    8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, redundant terminals, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    MBHC-FB-8R.YO*
    Compact Fieldbus Power Hub Motherboard for Yokogawa ALF111
    8 segments, redundant, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
    
    R2-SP-IC*
    Segment Protector for Cabinet Installation
    4 ... 12 outputs Ex ic (FISCO or Entity) or non-incendive (Div 2), Advanced fault isolation at the spur, Segment Protector in Zone 2/Div. 2, Instruments in Zone 2/Div. 2 or Zone 1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    R4D0-FB-IA*
    FieldBarrier? for Cabinet Installation
    FieldConnex? FieldBarrier?, 8 ... 12 outputs Ex ia IIC, FISCO and Entity, Advanced fault isolation and diagnostics at the spur, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    R8D0-MIO-Ex12.FF*
    Multi-Input/Output Device for Cabinet Installation
    For discrete inputs and outputs, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1
    
    R8D0-MIO-Ex12.PA*
    Multi-Input/Output Device for Cabinet Installation
    For discrete inputs and outputs, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA
    
    RD0-FB-Ex4.*
    FieldBarrier?
    4 outputs Ex ia IIC, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, Short circuit current limitation per output, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    RD0-TI-Ex8.FF.*
    Temperature Multi-Input Device for Cabinet Installation
    For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1
    
    RD0-TI-Ex8.PA.*
    Temperature Multi-Input Device for Cabinet Installation
    For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA
    
    SCP-LBF-IA1.36.IE*
    Fieldbus Surge Protector, Field Installation on Spur
    Pluggable, mounts between device coupler and spur cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    SPJB-**-AL*.***
    Segment Protector Junction Box, Aluminum
    Intrinsically safe (Ex ic)/non-incendive outputs, Anodized aluminum, IP67, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    SPJB-**-CS*.***
    Segment Protector Junction Box, Carbon Steel
    Intrinsically safe (Ex ic)/non-incendive outputs, Carbon steel, NEMA 4, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    SPJB-**-FB*.***
    Segment Protector Junction Box, Polyester (GRP)
    Intrinsically safe (Ex ic)/non-incendive outputs, Glass fiber reinforced polyester, NEMA 4x, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    SPJB-**-PCW.***
    Segment Protector Junction Box, Polycarbonate
    Intrinsically safe (Ex ic)/non-incendive outputs, Impact resistant polycarbonate, NEMA 4x, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    SPJB-**-SS*.***
    Segment Protector Junction Box, Stainless Steel
    Intrinsically safe (Ex ic)/non-incendive outputs, Stainless steel, brushed NEMA 4x, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    TCP-LBF-IA1.36.IE*
    Fieldbus Surge Protector, Field Installation on Trunk
    Pluggable, mounts between device coupler and trunk cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA
    
    TPH-LBF-IA1.36.DE*
    Fieldbus Surge Protector, Trunk Installation on Power Hub
    Pluggable, mounts between Power Hub and trunk cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield direct, For FOUNDATION Fieldbus H1 and PROFIBUS PA

    上海創(chuàng)弗實業(yè)有限公司專注于安川伺服電機,羅斯蒙特變送器羅斯蒙特分析儀,庫伯勒編碼器等

  • 詞條

    詞條說明

  • MTL MTL5553 MTL MTL838C 9101-22-PS、9101-CA-PS、9107-CA-PS

    MTL MTL5553?MTL MTL838C 9101-22-PS、9101-CA-PS、9107-CA-PSMTL MTL5553?MTL MTL838C 9101-22-PS、9101-CA-PS、9107-CA-PS、9108-22-PC、9108-22-PS、9108-CA-PC、9108-CA-PS、9109-CA-PS、9121- IS-PC、9121-IS-PS

  • 羅斯蒙特396/396P/396R傳感器 pH/ORP

    羅斯蒙特396/396P/396R傳感器 pH/ORP 羅斯蒙特396/396P/396R傳感器 pH/ORP型號:TUpH? 396/396P/396R 可抽取式/浸入式/插入式-pH/ORP 傳感器 ? SILCORE?2三重密封技術(shù)-提高傳感器在高溫工況下的使用壽命; ? 工作壓力高-三種型號傳感器,在 100°C(212°F)條件下,大工作壓力為 150psig(1136KPa 絕壓);

  • KFD2-HLC-Ex1.D倍加福KFD2-SOT3-Ex1.LB

    KFD0-HMS-16 HART Multiplexer Slave 16-channel, No external power required, HART field device input (revision 5 to 7), Used with HART Multiplexer Master KFD2-HMM-16, Up to SIL 3 acc. to IEC 61508 KFD0-

  • DME4000-112

    DME4000-211訂貨號:1029790產(chǎn)品系列:DME4000產(chǎn)品系列:遠程距離傳感器 測量范圍:0.15 m...130 m,在反光膜“Diamond Grade”上 重復精度:2 mm 準確度:±5 mm 輸出時間:1 ms 通訊接口:SSI 連接類型:插頭,M16,8針 電流消耗:在24 V DC<250 mA DME4000-112 類型:DME4000-112訂貨號:1029788

聯(lián)系方式 聯(lián)系我時,請告知來自八方資源網(wǎng)!

公司名: 上海創(chuàng)弗實業(yè)有限公司

聯(lián)系人: 張曉龍

電 話: 18001664790

手 機: 18001664790

微 信: 18001664790

地 址: 上海松江方松辰塔路2號

郵 編:

網(wǎng) 址: chuangfusy.b2b168.com

八方資源網(wǎng)提醒您:
1、本信息由八方資源網(wǎng)用戶發(fā)布,八方資源網(wǎng)不介入任何交易過程,請自行甄別其真實性及合法性;
2、跟進信息之前,請仔細核驗對方資質(zhì),所有預付定金或付款至個人賬戶的行為,均存在詐騙風險,請?zhí)岣呔瑁?
    聯(lián)系方式

公司名: 上海創(chuàng)弗實業(yè)有限公司

聯(lián)系人: 張曉龍

手 機: 18001664790

電 話: 18001664790

地 址: 上海松江方松辰塔路2號

郵 編:

網(wǎng) 址: chuangfusy.b2b168.com

    相關(guān)企業(yè)
    商家產(chǎn)品系列
    • 產(chǎn)品推薦
    • 資訊推薦
    關(guān)于八方 | 八方幣 | 招商合作 | 網(wǎng)站地圖 | 免費注冊 | 一元廣告 | 友情鏈接 | 聯(lián)系我們 | 八方業(yè)務(wù)| 匯款方式 | 商務(wù)洽談室 | 投訴舉報
    粵ICP備10089450號-8 - 經(jīng)營許可證編號:粵B2-20130562 軟件企業(yè)認定:深R-2013-2017 軟件產(chǎn)品登記:深DGY-2013-3594
    著作權(quán)登記:2013SR134025
    Copyright ? 2004 - 2025 b2b168.com All Rights Reserved